DENSITÉ series HCO-1822 HD/SD/ASI Change Over with Clean Switch and ALC Guide to Installation and Operation M955-9900-100
GUIDE TO INSTALLATION AND OPERATION 6 | HCO-1822 3.3 Local control using the Densité frame control panel 3.3.1 Overview Push the SELECT button o
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 7 3.4 Remote control using iControl The operation of the HCO-1822 may be controlled using Miranda’
GUIDE TO INSTALLATION AND OPERATION 8 | HCO-1822 Icon 3 – Input 1 status • A: Green - Status OK; format shown • B: Red – Error Icon 4
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 9 1. Manual switch Manually switches the HCO-1822 output between the two possible sources: input 1
GUIDE TO INSTALLATION AND OPERATION 10 | HCO-1822 • NOTE: for certain errors, the switch-over is delayed by 0.5 second beyond the selected durati
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 11 Figure 3.9 Alarms panel 3.4.3 The Alarms panel The HCO-1822 continuously monitors the condition
GUIDE TO INSTALLATION AND OPERATION 12 | HCO-1822 Video – Video Error alarm This error is always ENABLED and the level set to 1, 2 or OFF. The fac
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 13 Video – Timing Error This error is generated if the timing offset between the output signal and
GUIDE TO INSTALLATION AND OPERATION 14 | HCO-1822 Video – Freeze Detect This error detects the presence of a signal freeze (i.e. no change in cont
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 15 .Audio – Silence CH1 (same for CH2-16) This error flags the continuous absence of sound level in
GUIDE TO INSTALLATION AND OPERATION HCO-1822 Electromagnetic Compatibility This equipment has been tested for verification of compliance with FCC P
GUIDE TO INSTALLATION AND OPERATION 16 | HCO-1822 In1->In2 Click the checkbox to force all alarm parameters for input 2 to match those set for
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 17 The graphic and the text at the top of the panel show the timing of the two inputs with respect t
GUIDE TO INSTALLATION AND OPERATION 18 | HCO-1822 3.4.6 The Reference panel The HCO-1822 output signals should always be genlocked to some referen
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 19 3.4.8 The Miranda ALC panel Minimizing loudness differences between segments in a playout channe
GUIDE TO INSTALLATION AND OPERATION 20 | HCO-1822 3.4.8.2 PGM1-4 tabs Loudness monitoring When turned ON, the loudness meters display the program i
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 21 Here’s the time-domain response of the ALC: ALC Pre-Amp Level A pre-amp stage is available in
GUIDE TO INSTALLATION AND OPERATION 22 | HCO-1822 3.4.9 The Fingerprint panel Fingerprinting technology on this card functions in conjunction with
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 23 Use a mouse to resize – you may also use your mouse to move and resize the window. Click within t
GUIDE TO INSTALLATION AND OPERATION 24 | HCO-1822 RALM Connections tab Use the radio buttons to turn the meter display ON (RALM) or OFF for the ind
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 25 3.4.11 The Thumbnail panel The thumbnail area displays thumbnail images for the inputs and outp
GUIDE TO INSTALLATION AND OPERATION HCO-1822 Table of Contents 1 HCO-1822 HD/SD/ASI Change Over with Clean Switch and ALC ...
GUIDE TO INSTALLATION AND OPERATION 26 | HCO-1822 Clean Switch Option – allows the HCO-1822 to make a glitch-free switch between its two inputs und
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 27 ALC – This option enables the Automatic Loudness Control feature of the HCO-1822. Note that this
GUIDE TO INSTALLATION AND OPERATION 28 | HCO-1822 3.4.14 The Alarm Config panel This panel allows the alarm reporting of the HCO-1822 to be config
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 29 Levels associated with these alarms: The pulldown lists may contain some or all of the following
GUIDE TO INSTALLATION AND OPERATION 30 | HCO-1822 Get alarm keys Click this button to open a save dialog where you can save a file containing a li
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 31 • Details…: Reports the Firmware version, service version, and panel version for this card
GUIDE TO INSTALLATION AND OPERATION 32 | HCO-1822 3.4.16 User Presets The User Preset controls allow the user to save and recover all configuratio
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 33 Copy Profile From: This line shows this HCO-1822 card, and identifies it by App server, Densi
GUIDE TO INSTALLATION AND OPERATION 34 | HCO-1822 Note: There is no need to select a profile using the Profile pulldown (e.g. current, User1, etc.
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 35 4 Specifications Video inputs (2) SIGNAL SD: SMPTE-259M-C (270Mbps), HD: SMPTE-292M (1.485, 1
GUIDE TO INSTALLATION AND OPERATION HCO-1822
GUIDE TO INSTALLATION AND OPERATION 36 | HCO-1822 ANNEX – HCO-1822 User Interface NO REAR / REF PRESENCE / BACKUP INPUT / BYPASS MODE / GPI
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 1 1 HCO-1822 HD/SD/ASI Change Over with Clean Switch and ALC 1.1 Introduction The HCO-1822 is a 2
GUIDE TO INSTALLATION AND OPERATION 2 | HCO-1822 1.3 Block Diagram The following block diagram shows the functionality of the HCO-1822. Fig
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 3 2 Installation 2.1 Installation in the Densité frame The HCO-1822 and its associated rear conn
GUIDE TO INSTALLATION AND OPERATION 4 | HCO-1822 The HCO-1822 provides two HD/SD SDI video outputs on BNC connectors, labeled PGM (program) and PVW
GUIDE TO INSTALLATION AND OPERATION HCO-1822 | 5 3 Operation 3.1 Control options The HCO-1822 can be controlled in different ways: • The local