ACCESS = Entry into a restricted area.
AUDIT TRAIL = A date/time stamped log of previous lock events.
CLOCK
• REAL TIME CLOCK = An accurate built-in clock that allows
date/time stamping of events. The clock can be slowed or
speeded up to fine tune long term accuracy to within three
minutes per year.
• CLOCK SETTINGS = Printout includes date, time, weekday,
and clock speed.
• CLOCK SPEED = The clock can be adjusted to allow faster/
slower speeds and therefore increasing clock accuracy.
CODE = Numeric sequence of numbers (such as: 1234) entered at
the keypad. If Star-Enter-Key is required, must be followed by a
[:] key.
• BASIC USER CODE = User Codes assigned to User Num-
bers 12+ (except Users 297-300). (Does not allow
programming)
• INSTALLER CODE = User Codes assigned to User Numbers
2 and 3. (Allows all programming except Master functions).
• INVALID CODE = A User Code that has not been
programmed in the lock.
• MANAGER CODE = User Codes assigned to User Numbers 4
through 6. (Allows most of the programming functions).
• MASTER CODE = User Code assigned to User Number 1.
Default (factory) Master Code is 123456. The User with the
Master Code has complete control of the lock.
• PRINT ONLY USER CODE = User Code assigned to Users
10 and 11. (Allows no programming except print functions).
• QUICK ENABLE USER 300 CODE = Refers to the User Code
entered by User 297 which (when entered at the keypad)
enables the User Code assigned to User 300 for one time
only.
• QUICK PC ACCESS CODE = Permits upload/download to
DL-Windows Software on a PC running Microsoft Windows.
Refers to the User Code for User 298.
• SERVICE CODE = User 300 User Code. Allows only one
entry, then needs to be re-enabled by the User 297 User
Code to regain access.
• SUPERVISOR CODE = User Codes assigned to Users 7, 8
and 9. Can only program day-to-day operation.
• USER CODE = Code used by Users. Code is 3 to 6 numeric
digits long, allowing controlled entry.
• VALID CODE = An entered User Code that has been
programmed in the device.
COM PORT = A computer serial communications port used to
communicate with the Lock and/or Data Transfer Module.
DATA TRANSFER MODULE (AL-DTM) = A device that permits
transfer of program/data between a computer and the lock.
DATE = Month, Day and Year entered as MMDDYY.
DAY OF WEEK = Sunday through Saturday (where 1 = Sunday and
7 = Saturday).
DEFAULT = Default settings are the original settings that were set
at the factory; in other words, it is the lock's original factory con-
dition when the lock was first taken out of its box. The default
settings are permanently encoded within the lock's fixed mem-
ory, and when the lock is first started, or when power is removed
and re-applied (see Wiring and Power-Up, page 11), the original
factory default settings are re-loaded and take effect.
DISABLE = Turn off.
DOOR NUMBER = Identification of each door with a specific
number. (Used with AL-DTM Transfer Module)
DOWNLOAD = Send data to lock or AL-DTM.
ENABLE = Turn on.
EVENTS = Recorded lock activity.
FUNCTION (also called Programming Functions) = are the
numbers used to program lock features (enabling/disabling
Users, User Groups, Passage Mode, Schedules, etc.).
GROUP
• USER GROUP = Defining a User to specific Groups, allows
User entry when the Group is allowed entry.
• GROUP 1 ENABLES GROUP 4 USERS = A Group 1 USER
CODE entry during a predefined schedule will allow access
to Group 4 Users.
• GROUP 1 PUTS UNIT IN PASSAGE = A Group 1 USER
CODE entry during a pre-defined schedule will unlock unit.
INSTALLER = See.... CODE, INSTALLER CODE.
KEYPAD = 10-numeric keys, : and special ; key.
• KEYPAD LOCKOUT = Keypad is programmed to lockout Us-
ers, for a specified period of time, when a specified number
of invalid User Codes are entered.
• KEYPAD PROGRAMMING = Ability to program the lock
through the keypad.
KEYPRESS = Pressing a button on the Lock’s Keypad.
LEVEL ABILITY = Predefined User Types (such as Master,
Installer, Manager, Supervisor, and Print Only User) have
specific abilities to program and/or control the lock.
LOCKOUT ATTEMPTS = A specified number of invalid User Code
entries (1-9), that will disable the keypad for a predefined period
of time. See… LOCKOUT TIME.
LOCKOUT TIME = A predefined time (1-60) seconds that the lock
will stop accepting User Codes, after a specified number of
invalid User Code entries. See… LOCKOUT ATTEMPTS.
LOG = See... AUDIT TRAIL.
MANAGER = See... CODE, MANAGER CODE.
MASTER = See... CODE, MASTER CODE.
PASSAGE = Allow anyone to pass through the door without USER
CODES (door is unlocked).
PRINTER (AL-IR1) = A printout device such as an infrared printer or
computer printer.
PROGRAM MODE = A mode allowing program/data to be entered
through the keypad. Only specific Users can program a lock
manually, by entering their USER CODE, followed by the [;]
key. To exit program mode, hold any key until repeated beeps
are heard.
SCHEDULE = A programmed operation (enable/disable, lock/
unlock, etc.) on a specific day (Sunday through Saturday) and
time.
SCHEDULES, QUICK = Any one of four most common types of
schedules can be programmed.
TIME = Hours and Minutes in the HHMM format.
TIME/DATE STAMP = A recorded date and time that an event
occurred.
TIMEOUT = Immediate operation for a specified number of hours.
UPLOAD = Receive data from the lock or AL-DTM.
USER = A person who has been provided with a USER CODE for
access through the door.
USER LOCKOUT, TOTAL = All Users (except for Master Code)
have been locked out.