CN-6000
Series
C-16
Parameter Default Parameter Default Parameter Default Parameter Default
OUT1 ---- AL1 10)0 AL3 10)0 hPEK ----
OUT2 ---- AL2 00)0 AL4 00)0 lPEK ----
Parameter Default Parameter Default Parameter Default Parameter Default
OUT1 ---- AL1 00)0 AL3 10)0 hPEK ----
OUT2 ---- AL2 00)0 AL4 10)0 lPEK ----
Parameter Default Parameter Default Parameter Default Parameter Default
IN-P aMA2 lOR1 0$00
1
0)00
ExIO 5P SPAN !000
UNIT ?C hOR1 2)00
1
1)00
AL-1 AT!A AvF 01
dUNT ?/O lOR2 0$00
1
0)00
AL-2 AT@A MAvF 04
L-RG 0$00 hOR2 2)00
1
1)00
AL-3 AT!A DI-K HOLD
H-RG 2)00 BAR OUT1 AL-4 AT@A COLR GRN
dP )0 lOU1 00)0 A-HY 001 BURN ON
L-SC 00)0 hOU1 10)0 InSF LIN USER STND
H-SC 10)0 lOU2 00)0 )PSI 0*00 LOCK OFF
IN-B 000 hOU2 10)0
Parameter Default Parameter Default Parameter Default Parameter Default
IN-P 50KH lOR1 0)00 hOU2 5)00 MAvF 04
dUNT KHZ hOR1 1)00 ExIO 5P DI-K HOLD
L-RG 0)00 lOR2 0)00 AL-1 AT!A COLR GRN
H-RG 5)00 hOR2 1)00 AL-2 AT!A USER STND
dP )00 BAR OUT1 AL-3 AT!A LOCK OFF
L-SC 0)00 lOU1 0)00 AL-4 AT!A
H-SC 5)00 hOU1 5)00 A-HY 001
IN-B 000 lOU2 0)00 SPAN !000
■ CN-610
(universal input)
■ CN-640
(pulse input)
٧
Monitoring mode
٧
Monitoring mode
٧
Program mode
٧
Program mode
■ Caution for using
Forconnectingthepower,useacrimpterminal(M3.5,min.
7.2mm).
Theconnectionofthisunitshouldbeseparatedfrom
thepowerlineandhighvoltagelineinordertoprevent
inductivenoise.
Installapowerswitchoracircuitbreakertosupplyorcut
offthepower.
Switchorcircuitbreakershouldbeinstallednearbyusers
forconvenientcontrol.
Donotusethisunitnearthehighfrequencyinstruments
(highfrequencyweldingmachine&sewingmachine,large
capacitySCRcontroller).
Whensupplyinginput,if
HHHH
or
LLLL
isdisplayed,
measuredinputmayhaveproblem.Turnoffthepowerand
checktheline.
Installationenvironment
Itshallbeusedindoors.
Pollutiondegree2
Altitudemax.2,000m
Installationcategory
Itmaycausemalfunctionifaboveinstructionsarenot
followed.
1.Displayedonlyforcurrenttransmissionoutput,alarmoutputmodel(CN-610
-C1/C2/R1/R2/R4).
2.Displayedonlyforvoltagetransmissionoutputmodel(CN-610
-V1/V2).
Proper usage
Factory default