TYPICAL APPLICATION: PDK3000
Using a normally open push-button switch to provide passage via the door strike, and the Auxiliary Output to trigger a
visual or audible device only when door is unlocked.
Wire nut connections are represented by a
wire with a spherical end, intersecting another
wire, as shown in the
following illustration:
=
+
+
PDK3000
Power Input
BLACK
PURPLE
BLUE
N/C
Com
Entry
Relay
Output
Remote
Release
Output
RED
Tamper Output
Mounted to
Housing
Auxiliary
Relay
Output
N/O
GRAY
N/O Push
Button
Switch
WHITE
WHITE
N/C
Alarm
System Zone
Programmed
for 24-Hour
Alarm
BLACK
WHITE
Com
N/O
ORANGE
Low Voltage
Light
Source/
Sounder
Device
AC/DCV
Light Source/
Sounder
Device Supply
Door
Strike
Door
Strike
Power
Supply
-
-
N/C
POWER SUPPLY OPTIONS
Emergency Exit
Switch
Emergency Exit
Switch
SUPPLY
Simplified Power Supply Option:
Transformer 12 to 24 VAC or DC
Recommended Supply Option:
Battery Backup 12 to 24V AC or DC
WARNING
In all cases, be sure to
allow for emergency exit
during a fire or AC power
failure.
Local jurisdictions may
require use of an access
power supply with battery
backup, with provisions
for timed emergency exit.
Operation
The Remote Input is used with a push-button switch
to allow passage.
The Auxiliary Relay is used to activate external ser-
vice.
Door strike is activated upon a successful code en-
try, Prox entry or push-button closure.
Required Programming
Enable Auxiliary Relay follows main Relay (1).