12
"Programmable Features" Screen - Remote tab
The "Remote Input" wires are two white wires located
inside the rear housing. When these two white Remote
Input wires are momentarily shorted, the PL6100
unlocks. These Remote Input wires are enabled at the
factory and are ready for use.
Program Remote Input Functions as follows:
Remote Release (Momentary)
Check to enable the Remote Input feature in the se-
lected PL6100 lock. Will cause the PL6100 to unlock
when the two white Remote Input wires are momentarily
shorted.
Remote Toggles Passage Mode
Remote Input activation toggles Passage Mode
(Passage Mode allows passage through the door
without the need for a valid proximity card to be pre-
sented).
Remote Input Disables Unit
Regardless of the current state of the lock, that state will
remain unchanged (and lock will be disabled) for the du-
ration of Remote Input switch closure.
Important: If this feature is enabled, power to the lock
MUST be provided from an external power supply.
Forced Lock Follows Remote Input
When Remote Input switch is closed, regardless of the
current state of the lock, the lock will lock for the dura-
tion of the Remote Input switch closure.
Important: If this feature is enabled, power to the lock
MUST be provided from an external power supply.
Forced Unlock Follows Remote Input
When Remote Input switch is closed, regardless of the
current state of the lock, the lock will unlock for the dura-
tion of the Remote Input switch closure.
Important: If this feature is enabled, power to the lock
MUST be provided from an external power supply.