Alarm Lock NETWORXPANEL Manual de instrucciones Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
19
; 4 5 :
45. Enable Passage Mode
(This Function enabled through keypad only)
; 4 6 :
46. Disable Passage Mode
(This Function enabled through keypad only)
47. Timed Passage Mode
(This Function enabled through keypad only)
; 4 7 ; [ _ _ _ ] :
(XXX Hours)
Function 45 allows passage through the door without the need for a User Code. Disable Passage Mode with Function 46.
Programmed Schedules will
override the state of the NETWORXPANEL when Functions 45 and 46 are used. If it is re-
quired that programmed schedules do not override Passage Mode, enable/disable Passage Mode using Functions 48/49.
Note: Because of the temporary nature of these features, Functions 45-47 can only be enabled using the keypad.
Passage Mode Enable/Disable - Schedule will Override
2
Hours must be between 1 - 999.
Function 47 allows passage through the door without the need for a User Code for the programmed amount of
time.
For example, if you wish your NETWORXPANEL to "unlock" the secured door ("unlocked" = "Passage Mode")
for the next 3 hours, enter Program Mode and press: ; 47 ; 003 :
2
PASSAGE MODE
CLOCK ADJUST
; 4 3 ; [ _ _ ] :
(seconds)
43. Speed Up Clock
(This Function enabled through keypad only)
; 4 4 ; [ _ _ ] :
(seconds)
44. Slow Down Clock
(This Function enabled through keypad only)
Number of seconds to adjust (speed up/slow down) the clock each day must be be-
tween 0-55 seconds.
Note: Repeated use of these Functions are not "cumulative" (this means, for exam-
ple, if the clock has already been set to speed up 10 seconds per day, and then is
found to need an additional 10 seconds, then program 20 seconds using Function 43).
Example 1: Clock is losing 13 seconds every day, enter:
; 4 3 ; 1 3 :.
This example assumes that the Clock Adjust setting was at the factory default of zero.
Example 2: Clock is gaining 13 seconds every day, enter:
; 4 4 ; 1 3 :.
This example assumes that the Clock Adjust setting was at the factory default of zero.
Example 3: To set the clock adjust setting back to the factory default of zero, enter
:
; 4 3 : or ; 4 4 :
Clock Adjust
4
Programming Functions (cont'd)
Clock Accuracy
The internal oscillator is factory calibrated to an
accuracy of ±5 minutes/year. Changes in ambi-
ent temperature may affect accuracy. If neces-
sary, the accuracy of the internal clock may be
adjusted by first updating the correct time via Func-
tion 39. After an interval of about 1 month, re-set the
correct time via Function 39 and then view the Audit
Log. Because the Audit Log displays both the "New
Clock Time" and the "Old Clock Time", a daily accu-
racy (in seconds) can be determined by taking the
difference in seconds between the "Old" and "New"
times divided by the number of days between the
two Function 39 entries. Note: Because the mini-
mum available adjustment is 1 second per day, the
inaccuracy of the clock must exceed about 6 minutes
per year before adjustment is necessary.
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 35 36

Comentarios a estos manuales

Sin comentarios