Alarm Lock ETPDLN Manual de instrucciones Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
ACTIVITY LED SOUNDER COMMENTS
Keypress 1 RED Flash 1 Beep Normal Operation
Access Granted or Remote Release 3 GREEN Flashes 3 Beeps
Remote release enabled through activa-
tion of relay
Invalid Code 6 RED Flashes 6 Beeps Re-enter User Code
Successful Program Entry 2 GREEN Flashes 2 Beeps When in Program Mode
Unsuccessful Program Entry 7 RED Flashes 7 Beeps When in Program Mode
Exit Program Mode 1 RED, 2 GREEN Flashes 10 Beeps
Valid but Disabled Code 1 GREEN, 4 RED Flashes 1 long, 5 short beeps Code exists in memory, but disabled
Low Battery
RED Flash during key
presses
Pulsing Beeps See page 10 before changing batteries
User Code Entered RED Flash
Sequence of 7 Beeps
followed by
4 slow Beeps
A clock error has been detected. Under
this condition, unexpected operation is
possible. Remove power and restart.
User Code Entered RED Flash
Sequence of 7 Beeps
followed by
5 slow Beeps
A memory error has been detected.
Under this condition, unexpected
operation is possible. Remove power and
restart.
Programming Key Sequence.
Programming
Information
General Program Mode Information
If a wrong key is pressed during code entry, press the ; key until the error sound is heard (7 short beeps), this will clear the entry. Re-
enter the key sequence again.
All program sequences are followed by the : key; 2 short beeps indicate a successful program sequence.
Enabling/Disabling Users (By User Number)
3. Disable User
; 3 ; [ _ _ _ ] :
4. Enable User ; 4 ; [ _ _ _ ] :
User Number must be between 2 and 5000.
NOTE: Will Enable/Disable users even if the user is associated with an enabled group.
2
Conventions Used in this Manual
LED and Sounder Indicators
The PDL6500 and ETPDLN locks provide visual and audible keypad feedback. With a fully charged battery, the LED and
sounder feedback is as follows:
Minimum Required Program Level
Program Levels are abbreviated as follows:
M = Master
4 = Installer
3 = Manager
2 = Supervisor
This Program Level abbreviation is the
minimum program level required to
access the particular Function. (The
higher the level, the more programming
tasks the User is allowed, with Master
allowing all tasks).
Function
Description
Function
Number
Function Name