WIRING THE DIGITAL I/O’S
The XARTU/5 comes standard with sixteen memory-mapped digital I/O lines. They
are programmable, in groups of eight, as inputs or outputs. Digital outputs can be
configured as simple discrete outputs, or as precisely timed pulse outputs.
Digital I/O Description
XARTU/5 Terminal Location
PortA0
1
PortA1
2
PortA2
3
PortA3
4
PortA4
5
PortA5
6
PortA6
7
PortA7
8
PortB0
9
PortB1
10
PortB2
11
PortB3
12
PortB4
13
PortB5
14
PortB6
15
PortB7
16
The four (4) opto module slots (opto1, opto2, opto3, and opto4) on the IOT60 board
can be used as inputs or outputs. Jumpers JP1, JP2, JP3, and JP4 determine the port
configuration for the opto module slots. In the up position, JP1, JP2, JP3, and JP4 are
configured for Ports A0, A1, A2, and A3 respectively. In the down position, JP1, JP2,
JP3, and JP4 are configured for Ports B0, B1, B2, and B3 respectively. LED1, LED2,
LED3, and LED4 are signal indications for the four opto module slots. The table below
shows the terminal wiring for the four opto module slots.
Opto Module Slots Description
XARTU/5 Terminal Location
Opto 1
HL1-1 (-)
HL1-2 (+)
83
84
Opto 2
HL2-1 (-)
HL2-2 (+)
87
88
Opto 3
HL3-1 (-)
HL3-2 (+)
81
82
Opto 4
HL4-1 (-)
HL4-2 (+)
85
86