23
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
Used with Function 61
•
Number of attempts before lockout must be 1-9 attempts.
•
The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
•
The attempt count is reset each time a valid code is entered.
Function 61 determines the length of time the keypad is locked-out after a series of
unsuccessful attempts (default is 18 seconds). Used with Function 60.
•
Lockout Time must be 1-60 seconds.
4
4
LOCKOUT
; 6 6 ;
[ _ _ ]
:
(Ambush Code)
66. Ambush Code
•
Ambush code must be 2 digits.
•
An error will sound if the Ambush Code matches the 1st two digits of any User Code.
See Function 67 for more information about the Ambush Function.
•
Factory default Ambush Code is 99.
3
AMBUSH
; 6 0 ; [ _ ] :
(Number of Attempts)
; 6 1 ;
[ _ _ ]
:
(Lockout Time)
62-65. Reserved
59. AL-DTM2 Door Number
•
Door Number must be between 1-96.
Note
: Door Number must be between 1-48
for AL-DTM (Version 1).
Factory default is 01.
Function 59 is for use with Alarm Lock’s AL-DTM2 Data Transfer Module. Using the AL-
DTM2, up to 96 locks can be Downloaded/Uploaded and History Logs can be retrieved.
Enter a door number for each lock. After configuring the AL-DTM2, using Alarm Lock's
DL-WINDOWS Software, any of the following data transfers can be initiated by plugging
the AL-DTM2 into the lock and simply entering the User Code for User 299 at the lock.
•
Upload Lock Program
•
Upload History Log
•
Download Lock Program
4
AL-DTM2
; 5 9 ; [ _ _ ] :
(Door Number)
Programming Functions (cont'd)