DL4100 Residency and Privacy Features
Privacy Feature Mode 1: (Door Normally Locked--Factory Default)
Programmable Through DL-Windows & Keypad
"Privacy Feature Mode 1" is designed to allow access to individuals with access codes and is typically used for rooms needing pri-
vacy from others such as bathrooms, dorms and meeting rooms (Factory Default).
Configuring the DL4100 for the "Privacy Feature Mode 1" will initially provide a normally locked state. To enter through a DL4100
monitored door the user must use an access code or key. Once inside, the user presses the button and automatically disables the
keypad from allowing another user to enter for a pre-programmed amount of time. The red LED on the exterior / outside of the lock
will blink indicating that the room is occupied. When the initial user exits, the DL4100 is automatically set back into the original locked
mode and allows access to any authorized users.
The disable time (lockout) for the DL4100 can be pre-programmed by the installer. The disable time can be programmed to disable
access code access for up to 250 minutes. All users 12 and higher are disabled when this feature is active. Users 1 - 11 or a key
can always override this lockout feature with their user codes.
Programming: Disable Keypad On Button Press
; 6 7 ; 3 5 :
Default "Time-Out Duration" is automatically set to 10 minutes. This time is the maximum time the "Privacy Feature" is enabled. To
set this duration, enter the following sequence with your desired time from 001-250 minutes.
Programming: Time-Out Duration
;
6
8
;
[ _ _ _ ]
:
************************************************************************
Residency Feature:
The "Residency Feature" is provided to prevent a person from unintentionally having the door lock behind them when stepping out-
side briefly. Typically used in retirement homes and college dormitories.
Configuring the DL4100 for the "Residency Feature" will initially provide a normally locked state. To enter through a DL4100 moni-
tored door the user must use an access code or key. The DL4100 will then re-lock when door is closed.
Turning the handle and exiting from the inside will unlock the DL4100 and set it to passage mode.
Any of the following will restore the lock to the normally secure mode.
1. The user returns, enters, and presses the button from the inside.
2. Someone already inside the premises presses the button.
3. Pre-programmed scheduling.
4. Entering a valid access code or locking with a key.
Programming: Clear Privacy Default
;
6
8
;
0
0
0
:
Programming: Leave Unlocked on Exit (Passage)
;
6
7
;
3
7
:
Cancel Passage on Button Press
; 6 7 ; 3 6 :
************************************************************************
Privacy Feature Mode 2: (Door Normally Unlocked)
Programmable Through Keypad Only; Not DL-Windows
"Privacy Feature Mode 2" is designed to allow access to all and is typically used for rooms needing temporary privacy from others
such as bathrooms, dorms and meeting rooms.
Configuring the DL4100 for the "Privacy Feature Mode 2" will initially provide a normally unlocked (passage mode) state. No access
code is necessary to enter. Once inside, the user presses the button and automatically disables the keypad from allowing another
user to enter for a pre-programmed amount of time. The red LED on the exterior / outside of the lock will blink indicating that the
room is occupied. When the initial user exits, the DL4100 is automatically set back into the original unlocked (passage) mode and
the DL4100 will allow new access to all.
The lockout time for the DL4100 can be pre-programmed by the installer. The lockout time can be programmed to disable access
code access for up to 250 minutes. All users 12 and higher are disabled when this feature is active. Users 1 - 11 or a key can al-
ways override this lockout feature with their codes.
Note:
Function 45 may only be programmed by using the keypad. In addition,
Programmed Schedules will override the state of the lock using Functions 45 and 46. If it is required that programmed schedules do
not override passage mode, Enable/Disable Passage Mode using Functions 48/49.
Programming: Clear Privacy Default
;
6
8
;
0
0
0
:
Programming: Disable Keypad On Button Press
;
6
7
;
3
5
:
Enable Passage Mode
;
4
5
:
Default "Time-Out Duration" is automatically set to 10 minutes. This time is the maximum time the "Privacy Feature" is enabled. To
set this duration, enter the following sequence with your desired time from 001-250 minutes.
Programming: Time-Out Duration
;
6
8
;
[ _ _ _ ]
:
(3 digits)
(3 digits)