To Disarm a Burglary Control Panel
90. Relay Activation
(Open Time Window)
; 9 0 ;
[ _ ]
;
[ _ _ _ _ ] :
(Day) (Time)
Functions 90 and 91 allow you to set up a window of time where if any
Group 1
User Code is entered within this window,
the relay will be activated for 2 seconds. This relay is for use with a Control Panel that has a key switch disarm option. For
additional information, see Group 1 Activated Features on page 30.
•
Also program Relay Function 6 using Function 67 (
; 6 7 ; 6 :
).
•
For
day
enter: 1 for Sunday
, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday,
8 for Monday to Friday
, 9 for Saturday and Sunday, and 0 for all days of week.
•
Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15).
Scheduled Relay Activation
(Group 1 Activated)
; 9 1 ;
[ _ ]
;
[ _ _ _ _ ] :
(Day) (Time)
91. Relay Activation
(Close Time Window)
SCHEDULES GROUP 1 ACTIVATED
3
Burglary
Control
Panel
Relay
Output
Switch
Input
External
Relay
Armed
Lug
Power
Alarm Panel with Switched Input for Toggled Arm/Disarm
NOTES
1. Group 1 Disarms a Burglary Control
Panel will always disarm an alarm
system. Arming should be performed
by other means (such as Alarm Panel
Keypad/Schedule).
2. Use a qualified electrical/alarm
specialist to review your current alarm
system and add additional components
as needed (such as a relay, wire,
resistors, connectors and/or diodes) and
re-program the operation of your alarm
system as needed.